976 resultados para Rapid diagnosis


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is a need to provide rapid, sensitive, and often high throughput detection of pathogens in diagnostic virology. Viral gastroenteritis is a serious health issue often leading to hospitalization in the young, the immunocompromised and the elderly. The common causes of viral gastroenteritis include rotavirus, norovirus (genogroups I and II), astrovirus, and group F adenoviruses (serotypes 40 and 41). This article describes the work-up of two internally controlled multiplex, probe-based PCR assays and reports on the clinical validation over a 3-year period, March 2007 to February 2010. Multiplex assays were developed using a combination of TaqMan™ and minor groove binder (MGB™) hydrolysis probes. The assays were validated using a panel of 137 specimens, previously positive via a nested gel-based assay. The assays had improved sensitivity for adenovirus, rotavirus, and norovirus (97.3% vs. 86.1%, 100% vs. 87.8%, and 95.1% vs. 79.5%, respectively) and also more specific for targets adenovirus, rotavirus, and norovirus (99% vs. 95.2%, 100% vs. 93.6%, and 97.9% vs. 92.3%, respectively). For the specimens tested, both assays had equal sensitivity and specificity for astrovirus (100%). Overall the probe-based assays detected 16 more positive specimens than the nested gel-based assay. Post-introduction to the routine diagnostic service, a total of 9,846 specimens were processed with multiplex 1 and 2 (7,053 pediatric, 2,793 adult) over the 3-year study period. This clinically validated, probe-based multiplex testing algorithm allows highly sensitive and timely diagnosis of the four most prominent causes of viral gastroenteritis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Leptospirosis is a globally important zoonotic infection caused by spirochaetes of the genus Leptospira. It is transmitted to humans by direct contact with infected animals or indirectly via contaminated water. It is mainly a problem of the resource-poor developing countries of the tropical and sub-tropical regions of the world but outbreaks due to an increase in travel and recreational activities have been reported in developed and more industrialized areas of the world. Current methods of diagnosis are costly, time-consuming and require the use of specialized laboratory equipment and personnel. The purpose of this paper is to report the validation of the 'Leptorapide®' test (Linnodee Ltd, Northern Ireland) for the diagnosis of human leptospirosis. It is a simple one-step latex agglutination assay performed using equal volumes of serum sample and antigen-bound latex beads. Evidence of leptospiral antibodies is determined within minutes. Agglutination is scored on a scale of 1-5 and the results interpreted using a score card provided with the kit. Validation has been performed with a large sample size obtained from individuals originating from various parts of the world including Brazil and India. The test has shown sensitivity and specificity values of 97·1% and 94·0%, respectively, relative to the microscopic agglutination test. The results demonstrate that Leptorapide offers a cost-effective and accurate alternative to the more historical methods of antibody detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A double antibody sandwich ELISA (DAS-ELISA) was developed and employed for simultaneous direct detection of infectious bursal disease virus (IBDV) from bursal samples and to measure the humoral response, using the same basic immunoreagents, the purified and non-purified antigen, capture antibody and chicken hyperimmune sera were prepared, and standardized for this purpose, the DAS-ELISA was applied to both 80 bursal suspensions and 224 corresponding serum samples from vaccinated and non-vaccinated commercial hocks, Bursae samples were collected at 2 weeks of age, and submitted to histological examination, virus isolation in specific pathogen-free chickens embryos, and the DAS-ELISA technique, Serum titres obtained in indirect ELISA and serum neutralization test were compared with those in DAS-ELISA, the agreement was 80% between DAS-ELISA, and the conventional techniques, with high sensitivity (87%) and specificity (90%).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Francisella tularensis, a small Gram-negative facultative intracellular bacterium, is the causative agent of tularaemia, a severe zoonotic disease transmitted to humans mostly by vectors such as ticks, flies and mosquitoes. The disease is endemic in many parts of the northern hemisphere. Among animals, the most affected species belong to rodents and lagomorphs, in particular hares. However, in the recent years, many cases of tularaemia among small monkeys in zoos were reported. We have developed a real-time PCR that allows to quantify F. tularensis in tissue samples. Using this method, we identified the spleen and the kidney as the most heavily infected organ containing up to 400 F. tularensis bacteria per simian host cell in two common squirrel monkeys (Saimiri sciureus) from a zoo that died of tularaemia. In other organs such as the brain, F. tularensis was detected at much lower titres. The strain that caused the infection was identified as F. tularensis subsp. holarctica biovar I, which is susceptible to erythromycin. The high number of F. tularensis present in soft organs such as spleen, liver and kidney represents a high risk for persons handling such carcasses and explains the transmission of the disease to a pathologist during post-mortem analysis. Herein, we show that real-time PCR allows a reliable and rapid diagnosis of F. tularensis directly from tissue samples of infected animals, which is crucial in order to attempt accurate prophylactic measures, especially in cases where humans or other animals have been exposed to this highly contagious pathogen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Determination of chloride concentration in sweat is the current diagnostic gold standard for Cystic Fibrosis (CF). Nanoduct(R) is a new analyzing system measuring conductivity which requires only 3 microliters of sweat and gives results within 30 minutes. The aim of the study was to evaluate the applicability of this system in a clinical setting of three children's hospitals and borderline results were compared with sweat chloride concentration. Over 3 years, 1,041 subjects were tested and in 946 diagnostic results were obtained. In 95 children, Nanoduct(R) failed (9.1% failure rate), mainly due to failures in preterm babies and newborns. Assuming 59 mmol/L as an upper limit of normal conductivity, all our 46 CF patients were correctly diagnosed (sensitivity 100%, 95% CI: 93.1-100; negative predicted value 100% (95% CI: 99.6-100) and only 39 non CF's were false positive (39/900, 4.3%; specificity 95.7%, 95%CI: 94.2-96.9, positive predicted value 54.1% with a 95%CI: 43.4-65.0). Increasing the diagnostic limit to 80 mmol/L, the rate fell to 0.3% (3/900). CF patients had a median conductivity of 115 mmol/L; the non-CF a median of 37 mmol/L. In conclusion, the Nanoduct(R) test is a reliable diagnostic tool for CF diagnosis: It has a failure rate comparable to other sweat tests and can be used as a simple bedside test for fast and reliable exclusion, diagnosis or suspicion of CF. In cases with borderline conductivity (60-80 mmol/L) other additional methods (determination of chloride and genotyping) are indicated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Calorimetry is a nonspecific technique which allows direct measurement of heat generated by biological processes in the living cell. We evaluated the potential of calorimetry for rapid detection of bacterial growth in cerebrospinal fluid (CSF) in a rat model of bacterial meningitis. METHODS: Infant rats were infected on postnatal day 11 by direct intracisternal injection with either Streptococcus pneumoniae, Neisseria meningitidis or Listeria monocytogenes. Control animals were injected with sterile saline or heat-inactivated S. pneumoniae. CSF was obtained at 18 hours after infection for quantitative cultures and heat flow measurement. For calorimetry, 10 microl and 1 microl CSF were inoculated in calorimetry ampoules containing 3 ml trypticase soy broth (TSB). RESULTS: The mean bacterial titer (+/- SD) in CSF was 1.5 +/- 0.6 x 108 for S. pneumoniae, 1.3 +/- 0.3 x 106 for N. meningitidis and 3.5 +/- 2.2 x 104 for L. monocytogenes. Calorimetric detection time was defined as the time until heat flow signal exceeded 10 microW. Heat signal was detected in 10-microl CSF samples from all infected animals with a mean (+/- SD) detection time of 1.5 +/- 0.2 hours for S. pneumoniae, 3.9 +/- 0.7 hours for N. meningitidis and 9.1 +/- 0.5 hours for L. monocytogenes. CSF samples from non-infected animals generated no increasing heat flow (<10 microW). The total heat was the highest in S. pneumoniae ranging from 6.7 to 7.5 Joules, followed by L. monocytogenes (5.6 to 6.1 Joules) and N. meningitidis (3.5 to 4.4 Joules). The lowest detectable bacterial titer by calorimetry was 2 cfu for S. pneumoniae, 4 cfu for N. meningitidis and 7 cfu for L. monocytogenes. CONCLUSION: By means of calorimetry, detection times of <4 hours for S. pneumoniae and N. meningitidis and <10 hours for Listeria monocytogenes using as little as 10 microl CSF were achieved. Calorimetry is a new diagnostic method allowing rapid and accurate diagnosis of bacterial meningitis from a small volume of CSF.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Atrial tachycardias (AT) during or after ablation of atrial fibrillation frequently pose a diagnostic challenge. We hypothesized that both the patterns and the timing of coronary sinus (CS) activation could facilitate AT mapping. METHODS AND RESULTS A total of 140 consecutive postpersistent atrial fibrillation ablation patients with sustained AT were investigated by conventional mapping. CS activation pattern was defined as chevron or reverse chevron when the activations recorded on both the proximal and the distal CS dipoles were latest or earliest, respectively. The local activation of mid-CS was timed with reference to Ppeak-Ppeak (P-P) interval in lead V1. A ratio, mid-CS activation time to AT cycle length, was computed. Of 223 diagnosed ATs, 124 were macroreentrant (56%) and 99 were centrifugal (44%). When CS activation was chevron/reverse chevron (n=44; 20%), macroreentries were mostly roof dependent. With reference to P-P interval, mid-CS activation timing showed specific consistency for peritricuspid and perimitral AT. Proximal to distal CS activation pattern and mid-CS activation at 50% to 70% of the P-P interval (n=30; 13%) diagnosed peritricuspid AT with 81% sensitivity and 89% specificity. Distal to proximal CS activation and mid-CS activation at 10% to 40% of the P-P interval (n=44; 20%) diagnosed perimitral AT with 88% sensitivity and 75% specificity. CONCLUSIONS The analysis of the patterns and timing of CS activation provides a rapid stratification of most likely macroreentrant ATs and points toward the likely origin of centrifugal ATs. It can be included in a stepwise diagnostic approach to rapidly select the most critical mapping maneuvers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Abstract Background Accurate malaria diagnosis is mandatory for the treatment and management of severe cases. Moreover, individuals with asymptomatic malaria are not usually screened by health care facilities, which further complicates disease control efforts. The present study compared the performances of a malaria rapid diagnosis test (RDT), the thick blood smear method and nested PCR for the diagnosis of symptomatic malaria in the Brazilian Amazon. In addition, an innovative computational approach was tested for the diagnosis of asymptomatic malaria. Methods The study was divided in two parts. For the first part, passive case detection was performed in 311 individuals with malaria-related symptoms from a recently urbanized community in the Brazilian Amazon. A cross-sectional investigation compared the diagnostic performance of the RDT Optimal-IT, nested PCR and light microscopy. The second part of the study involved active case detection of asymptomatic malaria in 380 individuals from riverine communities in Rondônia, Brazil. The performances of microscopy, nested PCR and an expert computational system based on artificial neural networks (MalDANN) using epidemiological data were compared. Results Nested PCR was shown to be the gold standard for diagnosis of both symptomatic and asymptomatic malaria because it detected the major number of cases and presented the maximum specificity. Surprisingly, the RDT was superior to microscopy in the diagnosis of cases with low parasitaemia. Nevertheless, RDT could not discriminate the Plasmodium species in 12 cases of mixed infections (Plasmodium vivax + Plasmodium falciparum). Moreover, the microscopy presented low performance in the detection of asymptomatic cases (61.25% of correct diagnoses). The MalDANN system using epidemiological data was worse that the light microscopy (56% of correct diagnoses). However, when information regarding plasma levels of interleukin-10 and interferon-gamma were inputted, the MalDANN performance sensibly increased (80% correct diagnoses). Conclusions An RDT for malaria diagnosis may find a promising use in the Brazilian Amazon integrating a rational diagnostic approach. Despite the low performance of the MalDANN test using solely epidemiological data, an approach based on neural networks may be feasible in cases where simpler methods for discriminating individuals below and above threshold cytokine levels are available.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: The diagnosis of invasive candidiasis is difficult because there are no specific clinical manifestations of the disease and colonization and infection are difficult to distinguish. In the last decade, much effort has been made to develop reliable tests for rapid diagnosis of invasive candidiasis, but none of them have found widespread clinical use. Results: Antibodies against a recombinant N-terminal fragment of the Candida albicans germ tube-specific antigen hyphal wall protein 1 (Hwp1) generated in Escherichia coli were detected by both immunoblotting and ELISA tests in a group of 36 hematological or Intensive Care Unit patients with invasive candidiasis and in a group of 45 control patients at high risk for the mycosis who did not have clinical or microbiological data to document invasive candidiasis. Results were compared with an immunofluorescence test to detect antibodies to C. albicans germ tubes (CAGT). The sensitivity, specificity, positive and negative predictive values of a diagnostic test based on the detection of antibodies against the N-terminal fragment of Hwp1 by immunoblotting were 27.8 %, 95.6 %, 83.3 % and 62.3 %, respectively. Detection of antibodies to the N-terminal fragment of Hwp1 by ELISA increased the sensitivity (88.9 %) and the negative predictive value (90.2 %) but slightly decreased the specificity (82.6 %) and positive predictive values (80 %). The kinetics of antibody response to the N-terminal fragment of Hwp1 by ELISA was very similar to that observed by detecting antibodies to CAGT. Conclusion: An ELISA test to detect antibodies against a recombinant N-terminal fragment of the C. albicans germ tube cell wall antigen Hwp1 allows the diagnosis of invasive candidiasis with similar results to those obtained by detecting antibodies to CAGT but without the need of treating the sera to adsorb the antibodies against the cell wall surface of the blastospore.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Human respiratory syncytial virus (HRSV) is the main cause of acute lower respiratory tract infections in infants and children. Rapid diagnosis is required to permit appropriate care and treatment and to avoid unnecessary antibiotic use. Reverse transcriptase (RT-PCR) and indirect immunofluorescence assay (IFA) methods have been considered important tools for virus detection due to their high sensitivity and specificity. In order to maximize use-simplicity and minimize the risk of sample cross-contamination inherent in two-step techniques, a RT-PCR method using only a single tube to detect HRSV in clinical samples was developed. Nasopharyngeal aspirates from 226 patients with acute respiratory illness, ranging from infants to 5 years old, were collected at the University Hospital of the University of Sao Paulo (HU-USP), and tested using IFA, one-step RT-PCR, and semi-nested RT-PCR. One hundred and two (45.1%) samples were positive by at least one of the three methods, and 75 (33.2%) were positive by all methods: 92 (40.7%) were positive by one-step RT-PCR, 84 (37.2%) by IFA, and 96 (42.5%) by the semi-nested RT-PCR technique. One-step RT-PCR was shown to be fast, sensitive, and specific for RSV diagnosis, without the added inconvenience and risk of false positive results associated with semi-nested PCR. The combined use of these two methods enhances HRSV detection. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Protein A containing Staphylococcus aureus was used to develop a coagglutination (COA) test for the detection and typing of foot and mouth disease virus (FMDV) O, A and C serotypes in infected cells and tissues. Different batches and amounts of guinea pig anti-FMDV sera were assessed to optimize the preparation of COA conjugates. The sensitivity and specificity of the COA Test for the detection of FMDV O, A and C serotypes and heterologous viruses was also characterized. Comparison between the COA Test and complement fixation test for the detection and typing of FMDV obtained from extracts of tongue epithelial tissues from infected cattle revealed high agreement in the results and indicated a potential application of the COA Test for the direct diagnosis of viruses.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: To evaluate the diagnostic accuracy of bronchoscopy in patients with clinical or radiological suspicion of tuberculosis who were unable to produce sputum or with negative sputum smear microscopy results. Methods: A prospective cross-sectional study involving 286 patients under clinical or radiological suspicion of having pulmonary tuberculosis and submitted to bronchoscopy-BAL and transbronchial biopsy (TBB). The BAL specimens were submitted to direct testing and culture for AFB and fungi, whereas the TBB specimens were submitted to histopathological examination. Results: Of the 286 patients studied, 225 (79%) were diagnosed on the basis of bronchoscopic findings, as follows: pulmonary tuberculosis, in 127 (44%); nonspecific chronic inflammation, in 51 (18%); pneumocystis, fungal infections, or nocardiosis, in 20 (7%); bronchiolitis obliterans organizing pneumonia, alveolites, or pneumoconiosis, in 14 (5%); lung or metastatic neoplasms, in 7 (2%); and nontuberculous mycobacterium infections, in 6 (2%). For the diagnosis of tuberculosis, BAL showed a sensitivity and a specificity of 60% and 100%, respectively. Adding the TBB findings significantly increased this sensitivity (to 84%), as did adding the post-bronchoscopy sputum smear microscopy results (total sensitivity, 94%). Minor post-procedure complications occurred in 5.6% of the cases. Conclusions: Bronchoscopy is a reliable method for the diagnosis of pulmonary tuberculosis, with low complication rates. The combination of TBB and BAL increases the sensitivity of the method and facilitates the differential diagnosis with other diseases.